Water pressure regulator and expansion tank installation by United Plumbing in Bella Vista, Arkansas

Failed Pressure Regulator Replaced in Bella Vista

Bella Vista, AR Water Pressure Regulators

The problem

Banging pipes, two failed toilet fill valves in a year, and a water heater T&P valve that kept weeping. The original pressure-reducing valve had failed wide open.

How we fixed it

  1. 01Gauge-tested static and running pressure at the hose bibb — 118 psi static.
  2. 02Replaced the failed PRV with a serviceable brass unit and set it to 65 psi.
  3. 03Added a thermal expansion tank to protect the water heater.
  4. 04Rechecked pressure at multiple fixtures and documented the readings for the homeowner.

The result

Quiet pipes, protected appliances, and no more surprise fixture failures. The whole visit took under three hours.